Products

FHD(AHD) *Our AHD series features a two-way valve configuration

FHD: No Power Required

Our power source-free FHD series dehumidifying equipment, using either atmospheric air drawn in by an ejector or dry purge air to regenerate the desiccant, offer a unique advantage over conventional air dehumidifying equipment. Their ability to steadily supply dry air at a low dew point makes our FHD series dehumidifying equipment the perfect choice for semiconductor production facilities and other applications that require high quality gases.

FHD System Flow Schematic

FHD System Flow Schematic

Specifications

Outlet dew point temperature
(with pretreatment)
-20 to -80°C at 1 atm
Outlet dew point temperature
(without pretreatment)
-20 to -60°C at 1 atm
Cycle time 8 to 24 hours
Operating temperatures 10 to 40°C
Priority control Available
Energy-saving features Extended pre-cooling/
post-warming process
Dry air purge All cycles
Gaseous fluid Compressed air
Explosion-proofing Steam
Use of gases other than air Possible depending on operating conditions
Regeneration pressure Near-atmospheric pressure
Special feature of regeneration system Ejector purge regeneration
Utilities Engine power supply/
steam
Low dew point/
-60°C or lower
Pre-cooler required
Service life of switching valve Long
Noise Fan
Footprint Moderate
   
   
   

 

Products